Setting up your AGO

AGO Film Processor · Starting with AGO

Everything you need before your first rolls is on this page, from putting AGO on the tank to updating the firmware. The quick start guide in the box covers the first run, and the full manual is on our Downloads page.

Assembling

Load your film onto the reels in the dark and put them in the Paterson tank first. Everything after that happens in room light.

1

Fit the rear stand

Put the rear stand on the Paterson tank before the AGO goes on.

2

Turn the funnel holes down

Hold the AGO so the funnel holes face down. They must face down every time you attach it.

3

Press it on from above

Stand the tank upright on a table and press the AGO down onto it from above with your body weight, until the rubber seal is fully on. Then lay it on a flat surface.

How the AGO, the funnel and the rear stand fit on a Paterson tank
4

Test it with water once

Before your first chemistry, fill the assembled tank with water and run a program. If no water comes out at the joint, the seal is complete.

Using an older Paterson tank? Its centre column can stop the film from developing. Check it first.

Pouring in

Pour each chemical in from the front of the AGO, not from the side of the screen. Then press START.

Right: pouring chemistry into the AGO from the front
Wrong: pouring chemistry into the AGO from the screen side

The Quick Pour Funnel clicks onto the tank and gives a wide opening that cuts down on splashes, which helps most with the larger volumes of C-41, E-6 and RA-4. It can stay on when you pour out.

Pouring out

When the timer reaches zero, it is time to pour out. You don't need to take the AGO off the tank.

Hold the tank and the AGO together and turn them over, so the chemistry runs out over the rim of the tank. To reuse it, pour it back into its bottle through a funnel.

Pouring chemistry out of the AGO and tank into a bottle through a funnel

Keep the membrane dry

A small membrane on the back of the AGO evens out the air pressure. It has to stay dry.

  • Never pour water onto the back of the AGO. If you see drops of water there, wipe or blow them off straight away.
  • When you wash the film under a running tap, keep the water away from the back. You can also take the AGO off and wash the tank on its own.
  • After each session, switch the AGO off and wipe it with a damp cloth. Rinse only the parts that touch chemistry, and never put the AGO in water.
Washing film under a running tap with the AGO on the tank

Cleaning and greasing the seal are covered in Maintenance of AGO.

How much chemistry

AGO agitates the reels with the tank lying on its side, so it needs less chemistry than turning the tank by hand. Use at least these volumes.

Paterson tank 35mm rolls 120 rolls Minimum with AGO
1-reel 1 – 250 ml
2-reel (Universal) 2 1 350 ml
Multi-reel 3 3 2 450 ml
Multi-reel 5 5 3 650 ml
Multi-reel 8 8 5 950 ml

With the 4×5 reel, use the listed volume exactly. Volumes for the other reels are in the full minimum chemical volumes chart.

WiFi and updating

AGO makes its own WiFi network. You join it from a phone or laptop to update the firmware or build your own programs. While you are connected to AGO, your device has no internet, so download what you need first.

1

Download the firmware

Get the latest file from the Downloads page. It ends in .bin, there is nothing to unzip.

2

Turn on WiFi on the AGO

Go to Settings → Firmware Update and switch on WiFi Web Server.

3

Connect

Join the network AGO (password 12345678). Your device may say there is no internet; stay connected. Open a browser and go to the address on the AGO screen, usually 10.10.10.1.

4

Update

Open the Update tab, choose the file and press Update. AGO restarts on its own. On a Mac, use Chrome for the upload.

5

Check the version

After the restart, Settings → Software version shows the new version.

Can't connect? Connecting AGO to Wi-Fi goes through the usual fixes. Updating from an older version has its own video in the firmware update guidance.

Still stuck?

Write to us with your serial number and what happened.

Write to us
AGO Film Processor

Starting with AGO

Drilling an extra Paterson funnel

Read

Getting started

Read

Assembling AGO and the tank

Read

Machine overview

Read

How much chemistry per tank

Read

All wiki articles

Your legal guarantee rights

europa.eu/youreurope/guarantees
EU legal guarantee notice

Legal guarantee. Minimum two-year legal guarantee protection for goods sold in the European Union.

Consumers can claim their rights under the legal guarantee of conformity, for example if goods: do not match the description; do not function as intended.

Sellers are liable for any lack of conformity which existed when the goods were delivered, and which becomes apparent within the legal guarantee period. Sellers in such a situation are required to offer: free repair or free replacement; in some cases, a price reduction or full reimbursement.

Some countries have a longer legal guarantee period. For second-hand goods, a shorter period may apply, but not less than one year. For more information on your rights in a specific country, scan the QR code below or ask the seller. europa.eu/youreurope/guarantees

What to do if you receive non-conforming goods: 1. Contact the seller as soon as possible to report the issue; 2. Provide proof of purchase, such as a receipt, invoice, or bank statement.

Sellers and producers may also offer commercial guarantees, which apply independently from the legal guarantee. For example, you may see this GARAN label representing a commercial guarantee of durability offered by the producer at no additional cost and covering the entire good.